Short answer: it depends on the material. Fiberglass and mineral wool won’t ignite, but the paper or foil facing on some batts will. Cellulose is paper, but it’s treated so it resists flame and smoldering. Spray foam is a plastic and does burn, which is why building codes require it to be covered in most places. Nothing in a house is truly fireproof, so the real question is how each type behaves in a fire and how to install it safely.
If you’re asking “is insulation flammable?” because you’re planning a project or you are worried about the insulation already in your attic, this guide gives you straight answers for Illinois and western Indiana homes.
Is Insulation Flammable? A Quick Comparison
| Material | Will it catch fire? | What happens in a fire | What keeps it safe |
| Fiberglass (unfaced) | No, it’s noncombustible | Starts to soften and melt at roughly 1,000°F | Keep it away from heat sources |
| Fiberglass (kraft or foil faced) | The facing can burn | Facing burns, glass fibers melt | Cover facing with drywall or another approved material |
| Mineral wool | No, it’s noncombustible | Holds up to about 2,150°F before melting | Keep it away from heat sources |
| Cellulose | Treated to resist flame, but can smolder if misused | Chars; may smolder if it contacts a heat source | Use a product that meets federal flame standards; keep clearances |
| Spray foam (open or closed cell) | Yes, it’s combustible | Burns hot with heavy smoke and toxic gases | Covered by a thermal or ignition barrier |
| Foam board (XPS, EPS, polyiso) | Yes, it’s combustible | Burns and melts | Covered by drywall or an approved barrier |
General guidance. Always check the product data sheet and your local building code.
Is Fiberglass Insulation Flammable?
No. The glass fibers in fiberglass insulation don’t catch fire. That covers several common questions:
Does fiberglass insulation burn? Will it burn? Can it burn? The glass itself won’t. If a fire gets hot enough, around 1,000°F to 1,100°F, the fibers soften and melt instead. A melted batt stops insulating and can leave a gap in the wall or ceiling.
The catch is the facing. Many batts come with a kraft paper or foil backing that works as a vapor retarder. Manufacturers state that standard kraft and foil facing will burn and must not be left exposed. Facing is supposed to sit tight against drywall, subfloor or another approved material. Owens Corning’s installation guide says the same. Exposed facing is a real problem in crawl spaces, unfinished basements and garages, and it’s one reason building codes don’t treat exposed kraft facing as acceptable.
Is fiberglass insulation fire resistant or fireproof? Fire resistant, yes, in the sense that it doesn’t fuel a fire. Fireproof, no. Typical unfaced batts are rated Class A for surface burning, with a flame spread of 25 and smoke developed of 50 on the standard ASTM E84 test, and they pass the ASTM E136 noncombustibility test. That tells you the material won’t feed a fire. It doesn’t mean it will survive one. Keep in mind that insulation isn’t what gives a wall its fire rating. The drywall does most of that job.
Faced or unfaced? Unfaced fiberglass has no combustible layer. If you need a vapor retarder, you can add a separate one, or choose faced batts and cover them properly. In open attics, crawl spaces and garages, unfaced or foil-scrim-kraft facing that’s tested for flame spread is the safer pick.
Is Spray Foam Insulation Flammable?
Yes. Spray foam is a polyurethane plastic, and it’s combustible whether it’s open-cell or closed-cell. Foam makers add flame retardants that slow ignition and limit how fast flames spread, but that’s different from being fireproof. Once foam does burn, it burns hot and fast and gives off dense smoke and toxic gases. Building codes require foam plastics to meet surface burning limits (flame spread of 75 or less and smoke developed of 450 or less), and they also require physical protection.
What the code asks for.
| Location | Typical requirement |
| Living spaces, finished basements, garages | A 15-minute thermal barrier, such as ½-inch drywall |
| Attics and crawl spaces that are only entered for service | A thermal barrier, or an ignition barrier, or a product tested and approved for exposed use |
| Rim joist, walls behind drywall | Usually covered by the drywall itself |
The six ignition barrier materials named in the International Residential Code are 1½ inches of mineral fiber insulation, ¼-inch wood structural panels, ⅜-inch particleboard, ¼-inch hardboard, ⅜-inch gypsum board and 16-mil corrosion-resistant steel. The American Chemistry Council’s guide to spray foam in attics and crawl spaces explains these rules and notes that passing fire tests doesn’t guarantee how a material behaves in a real fire.
Many foam products are approved for exposed use with a special coating. Some installers apply an intumescent paint that swells when heated to protect the foam. Ask for the product’s evaluation report so you know the exact coating, thickness and where it’s approved.
Fire risk during installation. The biggest spray foam fire danger is often on installation day, not years later. Foam sprayed too thick in one pass, or hot work like welding, torch soldering or grinding near fresh foam, can start a fire. A trained crew follows the manufacturer’s pass-thickness limits and keeps ignition sources away. This is another reason we don’t recommend DIY foam on anything big. Read our closed-cell spray foam pros and cons and spray foam insulation page for more.

Is Cellulose Insulation Flammable?
Cellulose is made mostly from recycled newspaper, so people assume it’s a fire hazard. The treated product is much safer than that sounds. Manufacturers add fire retardants, most often boric acid, borax or ammonium sulfate, to resist both open flame and slow smoldering.
There’s a federal standard. In the 1970s, cellulose insulation was involved in home fires, especially when it was installed too close to recessed lights and other heat sources. In response, the Consumer Product Safety Commission set a mandatory standard (16 CFR Part 1209) for cellulose made after October 1979. The rule covers flame resistance, smoldering and corrosiveness, and it requires a flame spread rating of 0 to 25. You can read the federal standard and the history in this NIH background document.
What to look for: a label on the bag that says the product meets the CPSC standard. Older, untreated or home-made paper insulation is a different story and should be replaced.
Where cellulose can still be a problem: against hot recessed lights, chimneys and flues, or near faulty wiring. Treated cellulose may smolder or char when it’s in contact with intense, steady heat. Good installers keep it back from heat sources. Our cellulose insulation page covers how we install it, and our post on wet cellulose explains another approach.
What About Mineral Wool and Foam Board?
Mineral wool (stone wool) is the most heat-tolerant common batt. It’s noncombustible and doesn’t melt until about 2,150°F, according to manufacturer data. It’s often used where fire resistance matters, and some products are tested to add time to a wall or floor assembly’s fire rating. It costs more than fiberglass.
Foam board (XPS, EPS and polyiso) is a plastic, so it burns. Codes generally require it to be covered by drywall or another approved barrier. This matters in basements, crawl spaces and garages where board is often left exposed.
What Do “Fireproof,” “Fire Resistant” and “Class A” Mean?
These words get used loosely, so here’s how to read them.
| Term | What it really means |
| Noncombustible | Won’t ignite or burn under test conditions (fiberglass and mineral wool, not their facings) |
| Fire resistant | Slows ignition or spread, but can still be damaged |
| Fireproof | No such thing for insulation. Anything can fail at high enough heat |
| Class A / flame spread 25 or less | A surface burning test result. It means the surface doesn’t spread flame quickly |
| Fire-resistance rating (1 hour, etc.) | A test of a whole wall or floor assembly, which is mostly about the drywall |
What Actually Starts Insulation Fires?
Insulation itself rarely starts a fire. A heat source or electrical fault does, and the insulation either helps or doesn’t. The common causes:
- Recessed lights. Lights that aren’t rated for insulation contact (IC-rated) can overheat. The usual rule is to keep insulation about 3 inches away from non-IC fixtures, or replace them with IC-rated ones.
- Chimneys and flues. Insulation needs a safe clearance from them. Masonry chimneys typically need about 2 inches, and many codes call for metal barriers. Follow your chimney maker’s instructions and local code.
- Old wiring. Many older homes in Champaign, Danville and Decatur still have knob-and-tube wiring. It shouldn’t be buried in insulation without an electrician checking it.
- Exposed kraft or foil facing near ignition sources.
- Hot work. Soldering pipes, welding or cutting near insulation. A crawl space fire can start from a plumber’s torch.
- Space heaters and other heat sources placed against insulation or stored belongings.
- Bath fans or vents that run into the attic and pour moisture and heat onto insulation.
Fire-Safety Checklist for Your Attic or Crawl Space
- Look for exposed paper or foil facing and cover it or replace it.
- Check that recessed lights are IC-rated, or that insulation is held back from them.
- Keep insulation clear of chimneys, flues and vents.
- Have an electrician check any knob-and-tube or damaged wiring before adding insulation.
- Don’t store flammable items against insulation.
- Ask that any exposed spray foam has the correct barrier or coating.
- If you see vermiculite insulation, don’t disturb it and call a licensed professional. Our attic insulation page has more.
- Make sure smoke alarms work on every level.
Choosing Insulation With Fire Safety in Mind
For most Illinois homes, there’s a simple approach. Use blown-in cellulose or unfaced fiberglass on the attic floor, with proper clearances. Use closed-cell spray foam where it makes the most sense, such as the rim joist and crawl space, with the required barrier. If fire performance is your top priority for a specific area, ask about mineral wool. Our crawl space insulation guide and crawl space encapsulation service explain where foam fits.
What to Do With Insulation After a Fire
Insulation exposed to fire, heavy smoke or the water used to put out a fire usually needs to be removed and replaced. Fiberglass that has melted won’t insulate. Water-soaked insulation grows mold. Have your home inspected before you re-insulate, and ask your insurance company what they cover.
Insulation Flammability FAQs
Is insulation flammable?
Some types are. Fiberglass and mineral wool aren’t, though the facing on faced batts is. Cellulose is treated to resist fire. Spray foam and foam board are combustible and must be covered.
Does insulation burn? Will insulation burn?
It depends on the type. Foam plastics burn, paper facing burns, and treated cellulose can char or smolder. Fiberglass and mineral wool don’t burn, but fiberglass can melt.
Is house insulation flammable?
Most modern home insulation is made to meet fire safety standards, but combustible materials like foam and kraft facing need protection. Check what you have and how it’s covered.
Is fiberglass insulation flammable?
No. The glass doesn’t burn. Paper or foil facing can.
Does fiberglass insulation burn?
The glass won’t. It melts at very high heat, around 1,000°F. The paper or foil backing can burn.
Is fiberglass insulation fire resistant?
Fire resistant in that it doesn’t fuel a fire, but not fireproof. It will melt in a hot enough fire.
Is spray foam insulation flammable?
Yes. It’s combustible. Codes require a thermal barrier, an ignition barrier or an approved coating, depending on where it’s installed.
Is cellulose insulation flammable?
Cellulose is paper-based, but it’s treated with fire retardants and must meet a federal flame and smolder standard. Keep it back from heat sources.
Which insulation is the most fire resistant?
Mineral wool, which doesn’t melt until about 2,150°F. Unfaced fiberglass is also noncombustible.
Does insulation make a house fire worse?
Combustible insulation, such as unprotected foam or exposed facing, can. Noncombustible insulation behind drywall typically doesn’t.
Questions About Insulation Safety in Your Home?
If you’re not sure what’s in your attic, walls or crawl space, we’re happy to take a look and tell you what’s there, what needs attention, and what your options are. Call Payless Insulation at (217) 304-2885 or request a free quote. We serve Champaign, Danville, Decatur, Bloomington, Lafayette, IN and nearby communities.